Fitting for both new and retrofit projects, SATEC’s Branch Feeder Monitor™,
is a multi-circuit power meter, monitoring up to 18 three-phase power circuits
or 54 single-phase, or any combination. The BFM-II utilizes High Accuracy
Current Sensors (HACS) and is ideal for a wide range of applications,
from monitoring medium-voltage substations through commercial multi-tenant billing
in shopping-centers or office buildings.
t is designed for DIN-rail mounting, equipped with built-in communication ports and
anti-tamper enclosures. Modular expansion allows installation of additional I/O modules
and power supply.
Power Meter | |
---|---|
Power: True RMS volts, amps, power, energy, power factor, neutral current and many more | |
Event and parameter data-logging | |
measurement at 50/60 Hz | |
Sampling frequency: 64 samples per cycle |
Harmonic Analyzer | |
---|---|
Voltage and current THD, TDD and K-Factor, | |
Voltage and current harmonic spectrum and angles, up to the 25th order harmonic |
Revenue Meter | |
---|---|
Class 0.5S / 0.5 accuracy per IEC 62053-22 / ANSI C12.20 for active energy | |
Anti-tamper design | |
Bills up to 18 individual three-phase clients or 54 single-phase clients or various combinations in between | |
Time-of-Use billing and logging: 8 energy/demand registers x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes per day, easy programmable tariff schedule | |
Automatic 120-day daily profile for import/export energy and maximum demand readings (total and tariff registers) for each submeter | |
Pulse reading via DI for water and gas meters |
Variable Current Inputs | |
---|---|
HACS: 40mA HACS CT designated inputs (available HACS ratings: 100A-3,000A) | |
RS5: inputs for specific split-core HACS CTs rated 5A | |
3V AC: inputs for Flex Clamps (Rogowski Coil) |
Voltage & Power Supply | |
---|---|
Nominal voltage: 120/208 – 277/480V AC (L-N/L-L) | |
Operating range: 70-561V AC 50/60 Hz (direct connection, L-L) | |
Self-Energized from measured voltage | |
Optional auxiliary power supply: 50-290V AC, 40*-290V DC | |
* Above 60°C – minimum 90V DC |
Dual Voltage Inputs | |
---|---|
Voltage Input Module: a set of 3-phase voltage inputs for metering parallel power sources | |
Calibrated at either 50 Hz or 60 Hz | |
every submeter can be assigned to one of the measured voltages. | |
rating: identical to main voltage inputs (70 – 571V AC, L-L) |
Communication Protocols | |
---|---|
Modbus | |
ASCII | |
BACnet | |
DNP3.0 | |
IEC 60870-5-101/104 |
Programmable Logical Controller | |
---|---|
Embedded programmable controller | |
4 control setpoints, programmable thresholds and delays for each submeter | |
Relay output control (for alarm and protection) | |
1 cycle response and update time |
Graphic Display Module (GDM) | |
---|---|
Optional 3.5” 320×240 pixel touch-screen graphic display |
Meter Security | |
---|---|
3 level password security for protecting meter setups and accumulated data from unauthorized changes | |
Anti-tamper design (wiring seal) |
Communication interfaces | |
---|---|
Built-in | |
RS485 | |
Ethernet (10/100Base-T) | |
USB (Type A) | |
Optional: | |
2G/3G modem |
Modular I/O | |
---|---|
Up to 72 DI | |
Up to 18 DO | |
4 Analog input option. |
Real Time Clock | |
---|---|
Built-in clock and calendar functions | |
Accuracy: < 5 sec/month @ 25°C |
Mounting | |
---|---|
DIN-rail |
No application images found.