The MBMet 901 series is designed & engineered for accuracy and stability.
From Atmospheric Air Temperature to Relative Humidity, Barometric Pressure,
Air Density, and Dew Point, the MBMet 901 series provides a Reliable Monitoring
solution for many Ambient Air Parameters. Each Sensor is individually calibrated
using High Grade reference devices and Test Generators to ensure a highly accurate
reading.The MBMet-901 Series is compliant to the standards and guidelines set out by
the World Meteorological Organisation (WMO).
The MBMet-901 Sensor has a Hydrophobic cap which allows only air to pass through it
and protects the internal electronics from Fine Dust and other particles.
The sensor uses the Latest Generation combined component for Temperature and Relative
Humidity from a Swiss Manufacturer which offers accurate measurements and stability.
The internal components of the sensor then process and filter the Data to provide the
final readings.
Sunlight's impact is mitigated by the MBMet 901 series Radiation Shield, assuring
measurements untainted by external factors. The Sensor is also compatible with most
other Radiation Shields available in the Market.The Sensor is also Tested to perform
in High Electromagnetic Interference Environments - ensuring Data accuracy in Harsh
Conditions.
The MBMet-901 Sensor offers an ideal solution for Many Applications -
Renewable Plants, Wind Resource Assessment, Electrical Substations,
HydroMeteorology, Agriculture, etc.
All MBMet Sensors can be Configured with our Free to Use Desktop Software
“MB Config”. This Software is Designed Specially to Configure and Troubleshoot all
MBMet Sensors. All Configuration Settings such as Modbus ID, Baud Rate, Parity,
Modbus Frame Analysis, Temperature Unit Selection, Heater Operation, along with
Real-Time Data Viewing can be achieved using this Advanced software. The MB Config
Software Can be Downloaded from the Downloads Section of the MB Config Software Page.
AMBIENT TEMPERATURE | |
---|---|
Measuring Range | -40°C to +125°C |
Resolution | 0.001°C |
Accuracy (Typical) |
±0.2°C |
Response Time | 0.2 |
Stability | <0.03°C per year |
DEW POIN | |
---|---|
Measuring Range | -40°C to 105°C |
Resolution | 0.001°C |
Accuracy | Calculated |
Response Time | 8-30s |
AIR DENSITY | |
---|---|
Accuracy | Calculation |
Calculated Time | 5s |
RELATIVE HUMIDITY | |
---|---|
Measuring Range |
0 to 100%RH |
Resolution | 0.001%RH |
Accuracy (At 25°C) |
±2%RH |
Response Time | 4s |
Stability | <0.2%RH per year |
BAROMETRIC PRESSURE | |
---|---|
Measuring Range |
300 to 1250 hpa |
Resolution |
0.001 hPa Accuracy |
Resolution | 0.001 hPa |
Accuracy | ±0.4 hPa |
Response Time | 0.1s |
Stability | ±1 hPa Per Year |